Strainers Manufacturer – Industrial Strainers

Y-strainers remove solid particles such as scale, weld slag and debris from a pipeline before they reach valves, pumps, meters and other equipment.

About our strainers

Y-strainers remove solid particles such as scale, weld slag and debris from a pipeline before they reach valves, pumps, meters and other equipment. A perforated screen inside the Y-shaped body traps the particles while the fluid passes through. UTC VALVES manufactures and supplies strainers alongside its valve range to protect valves and process equipment.

Y-type strainer supplied by UTC VALVES
Product image: UTC VALVES

Product specifications

Y-type strainer

Y-type strainer
Product image: UTC VALVES
Size range ½” to 16″ (flanged and butt-weld ends)
Pressure rating Class 150 to 2500
Body material ASTM A216 WCB / A351 CF8 / A351 CF8M
Screen SS 304 / SS 316
Y-type strainer – sectional drawing
Sectional / general arrangement drawing – tap to enlarge.

Dimensions & technical details (mm)

Size (in) Size (mm) A B C D Screen area (cm²) Weight (kg) approx.
1″ 25 165 100 155 ½” 77 4
1-1/2″ 40 203 118 180 ½” 120 6.5
2″ 50 229 145 225 ½” 189 10
2-1/2″ 65 279 159 250 ½” 274 16
3″ 80 318 200 315 ½” 452 24
4″ 100 368 302 490 ½” 742 46
5″ 125 425 312 495 ¾” 1120 56
6″ 150 470 415 700 ¾” 1648 75
8″ 200 597 450 715 ¾” 2565 120
10″ 250 673 560 910 ¾” 3923 205
12″ 300 775 675 1110 ¾” 6033 345
14″ 350 860 759 1245 ¾” 7850 480
16″ 400 1125 984 1650 1″ 10178 570

Weights and dimensions are for reference only.

Material list

No. Part Carbon steel SS 304 SS 316 Qty
1 Body ASTM A 216 WCB ASTM A 351 CF8 ASTM A 351 CF8M 1
2 Cover ASTM A 216 WCB ASTM A 351 CF8 ASTM A 351 CF8M 1
3 Element SS 304 SS 304 SS 316 1
4 Stud & nut ASTM A 193/194 Gr. B7/2H ASTM A 193/194 Gr. B7/2H (zinc plated) ASTM A 193/194 Gr. B7/2H (zinc plated) –
5 Gasket SS 316 SPW with Gr. filler SS 316 SPW with Gr. filler SS 316 SPW with Gr. filler 1
6 Drain plug ASTM A 105 ASTM A 182 F304 ASTM A 182 F316 1

How it works

Flow enters the body and passes through a cylindrical screen held in the angled leg of the Y. Particles larger than the screen openings stay inside the screen. As debris builds up, the pressure drop across the strainer rises. The screen is cleaned by isolating the line and removing the bolted cover, or debris can be flushed out through a blow-off drain connection where one is fitted.

Types and configurations

  • Cast Y-type strainers with flanged ends
  • Butt-weld end Y-strainers
  • Horizontal or vertical installation (as per catalog design)
  • Options: differential pressure (DP) tappings or gauge, drain valves, pleated filter elements and magnetic screen inserts

Construction and design features

  • Wall thickness as per API 600 (as stated in our catalogue)
  • Compact design with large screening capacity
  • Precision-machined screen seats
  • Bolted cover with blow-off drain connection
  • Open area of the perforated sheet greater than 4 × pipe area (manufacturer data)

Materials of construction

  • Body and cover: ASTM A216 WCB, ASTM A351 CF8 or CF8M
  • Screen element: SS 304 or SS 316
  • Gasket: SS 316 spiral wound with graphite filler
  • Studs and nuts: ASTM A193/A194 Gr. B7/2H

Material grades listed are those commonly specified in industry for this valve type. Availability of each grade is subject to confirmation by UTC VALVES for every enquiry.

End connections

  • Flanged ends, drilled to ASME, DIN, BS or IS templates (as per catalog options)
  • Butt-weld ends

Pressure classes and standards

Pressure classes offered by UTC VALVES: listed for each model in the product specifications below.

Standards commonly referenced for this valve type include ASME B16.34 and ASME B16.5 (flanged ends), with wall thickness to API 600 as stated in our catalogue. These are industry references; they do not indicate that UTC VALVES or its products hold certification. Compliance documents are provided per order where available.

Industrial applications

  • Protecting control valves and safety valves
  • Pump suction protection
  • Flow meter and steam trap protection
  • Removing construction debris during plant start-up

Industries served

  • Oil & gas
  • Power generation
  • Refining & petrochemicals
  • Chemical processing
  • Water & utilities

See all industries we serve

Information to include in your enquiry

A complete enquiry helps us respond with an accurate offer for strainers:

  • Valve type and configuration
  • Nominal size (NPS / DN)
  • Pressure class or rating
  • Body, trim and seat materials
  • End connection and facing
  • Operator: lever, handwheel, gear or actuator
  • Service fluid, design pressure and temperature
  • Applicable standard or project specification
  • Quantity and required delivery date
  • Inspection, testing and documentation requirements (e.g. material test certificates, third-party inspection)

Strainers: frequently asked questions

When should a strainer be cleaned?

When the pressure drop across it rises noticeably above the clean value. Fitting DP tappings or a gauge makes this easy to monitor.

How should a Y-strainer be installed in a horizontal line?

With the screen leg pointing downwards so debris collects at the bottom of the screen and can be removed through the drain. For steam service, the leg is often turned to the side to avoid collecting condensate; follow the project piping guidance.

Can strainers be supplied with a finer screen?

Screen and mesh options can be specified with the enquiry. Pleated filter elements and magnetic inserts are listed as options in our catalogue.

Request a quote for strainers

Send your specification, datasheet or bill of materials. Our team reviews every enquiry and responds with availability and a quotation.

Request a Quote

WhatsApp us