Check Valves Manufacturer – Industrial Check Valves

Check valves, also called non-return valves, allow flow in one direction and close automatically when flow stops or reverses.

About our check valves

Check valves, also called non-return valves, allow flow in one direction and close automatically when flow stops or reverses. They need no handwheel or actuator: the flowing fluid opens them, and reverse flow or gravity closes them. UTC VALVES manufactures and supplies check valves to protect pumps, compressors and process equipment from backflow.

Cast steel check valve supplied by UTC VALVES
Product image: UTC VALVES

Product specifications

Cast steel swing check valve

Cast steel swing check valve
Product image: UTC VALVES
Body material WCB / WC6 / LCB / CF8 / CF8M / CF3 / CF3M etc.
Pressure rating Class 150 to 2500
Design standard BS 1868 / ASME B16.34 / API 6D
Inspection & testing API 598 / API 6D / BS EN 12266-1
End connection Flanged / butt weld / RTJ
Size range 2″ to 20″
Options Bypass, floor stand
Dimensions Face-to-face ASME B16.10; flanges ASME B16.5; butt-weld ends ASME B16.25
Cast steel swing check valve – sectional drawing
Sectional / general arrangement drawing – tap to enlarge.

Dimensions & technical details (mm)

Parameter Class 2″ 3″ 4″ 5″ 6″ 8″ 10″ 12″ 14″ 16″ 18″ 20″
Face to face (L) 150# 203 241 292 356 406 495 622 698 787 914 978 978
300# 267 318 355 400 444 533 622 711 838 864 978 1016
600# 292 355 431 508 558 660 787 838 889 991 1092 1194
900# 368 381 457 559 610 737 838 965 1029 1130 1219 1321
1500# 368 470 546 673 705 832 991 1130 1257 1384 1537 1664
Height (H) approx. 150# 155 200 225 245 260 305 390 410 435 530 570 625
300# 180 225 240 275 310 370 410 440 500 545 605 675
600# 190 250 260 310 350 420 490 525 580 630 690 810
900# 195 260 275 320 370 435 520 530 580 660 782 935
1500# 220 290 310 350 410 485 530 590 620 790 950 1150
Weight (kg) approx. 150# 15 33 45 77 90 118 220 340 470 575 790 920
300# 28 55 72 108 158 232 350 449 645 800 972 1352
600# 33 55 90 120 210 320 550 790 950 1240 1814 2267
900# 55 90 135 165 295 525 900 1075 1225 1425 1900 2510
1500# 70 115 175 180 370 680 1050 1180 1325 1530 2040 2670

Material list

No. Part Material (ASTM specification)
1 Body WCB / WC6 / WC9 / CF8 / CF8M / CF3 / CF3M / LCB
2 Cover WCB / WC6 / WC9 / CF8 / CF8M / CF3 / CF3M / LCB
3 Disc WCB / WC6 / WC9 / CF8 / CF8M / CF3 / CF3M / LCB
4 Hinge WCB / WC6 / WC9 / CF8 / CF8M / CF3 / CF3M / LCB
5 Hinge pin SS 410 / SS 304 / SS 304L / SS 316L
6 Seat ring F6a / A105 / LF2 / SS 316 / SS 304 / F51
7 Disc nut Carbon Steel / Stainless Steel
8 Washer Carbon Steel / Stainless Steel
9 Gasket Spiral Wound SS 316 + Graphoil
10 Cover stud B7 / B7M / B8M / B8 / L7
11 Cover nut 2H / 8 / 8M / 7

How it works

Forward flow lifts or swings the closure element (disc, plate, piston or ball) off its seat. When forward flow drops, the element returns to the seat under gravity, spring force or reverse pressure, preventing backflow. The minimum pressure needed to open the valve is known as the cracking pressure.

Types and configurations

  • Swing check – a hinged disc swings open with flow
  • Lift / piston check – the disc rises vertically off the seat; common on small-bore lines
  • Dual-plate (wafer) check – two spring-loaded half plates; compact and lightweight
  • Tilting disc check – reduced slam characteristics
  • Ball check and nozzle (axial) check valves for specific duties

Construction and design features

  • Automatic operation with no external power
  • Bolted cover for internal access on swing designs
  • Spring assistance on dual-plate and nozzle types to reduce slam
  • Selection of disc and seat materials to suit fluid
  • Wafer, lug, flanged and welded body styles

Materials of construction

  • Cast carbon steel (e.g. ASTM A216 WCB)
  • Cast stainless steel (e.g. ASTM A351 CF8M)
  • Forged steel for small sizes (e.g. ASTM A105)
  • Ductile iron or bronze for water services, on request
  • Availability of each grade is subject to confirmation by UTC VALVES for every enquiry.

Material grades listed are those commonly specified in industry for this valve type. Availability of each grade is subject to confirmation by UTC VALVES for every enquiry.

End connections

  • Flanged RF or RTJ
  • Wafer and lug styles (dual-plate)
  • Butt-weld
  • Socket-weld and threaded (small sizes)

Pressure classes and standards

Pressure classes offered by UTC VALVES: listed for each model in the product specifications below.

Standards commonly referenced for this valve type include API 594 (check valves: flanged, lug, wafer and butt-welding), API 6D, BS 1868, ASME B16.34 and API 598. These are industry references; they do not indicate that UTC VALVES or its products hold certification. Compliance documents are provided per order where available.

Industrial applications

  • Pump discharge protection
  • Compressor outlet lines
  • Boiler feedwater systems
  • Cooling water circuits
  • Pipeline backflow prevention

Industries served

  • Water & wastewater
  • Oil & gas
  • Power generation
  • Desalination
  • Chemical processing

See all industries we serve

Information to include in your enquiry

A complete enquiry helps us respond with an accurate offer for check valves:

  • Valve type and configuration
  • Nominal size (NPS / DN)
  • Pressure class or rating
  • Body, trim and seat materials
  • End connection and facing
  • Operator: lever, handwheel, gear or actuator
  • Service fluid, design pressure and temperature
  • Applicable standard or project specification
  • Quantity and required delivery date
  • Inspection, testing and documentation requirements (e.g. material test certificates, third-party inspection)

Check Valves: frequently asked questions

Can a swing check valve be installed vertically?

Only in vertical lines with upward flow, and only where the design permits it. Downward-flow installations need a spring-assisted design. Confirm orientation with the valve datasheet.

What is check valve slam?

Slam is the sudden closure of the disc when flow reverses, which can create a pressure surge (water hammer). Fast-closing designs such as dual-plate or nozzle check valves help reduce it.

Where should a check valve be placed relative to a pump?

Typically on the pump discharge, upstream of the isolation valve, so the check valve can be isolated for maintenance. Follow the project piping design.

Related valve categories

Request a quote for check valves

Send your specification, datasheet or bill of materials. Our team reviews every enquiry and responds with availability and a quotation.

Request a Quote

WhatsApp us